Eranntex builds oxygen (O2) monitoring into 14 models—8 portable, 2 transportable and 4 fixed—covering 0–30 %Vol, 0–100 %Vol and trace ppm measuring ranges with diffusion or pump sampling. Most buyers start with one question: are you protecting people entering or working in an area, or monitoring a closed process line? Personal and confined-space monitors guard against deficiency and enrichment inside the 0–30 %Vol range, while inerting, nitrogen purging and pipeline projects rely on fixed detectors, sample conditioning or 0–100 %Vol and ppm options.

Where oxygen hazards occur and what they do

Normal air holds roughly 20.9 %Vol oxygen, and neither oxygen depletion nor oxygen enrichment gives any smell or visual warning. Deficiency extends well beyond nitrogen or argon leaks: UK HSE L101 notes that rusting inside closed steel vessels, fermentation, stored grain or timber, welding, and inert-gas purging all strip oxygen from enclosed air—even leaning a head into a space can prove fatal. When 20.9 %Vol air is uniformly diluted by an oxygen-free gas, each 1 percentage-point drop in O2 corresponds to about 4.8 %Vol of displacing gas, reaching roughly 6.7 %Vol at 19.5 %Vol O2. Between 1992 and 2002, a US CSB review recorded 85 workplace nitrogen asphyxiation incidents causing 80 deaths and 50 injuries, more than 60% in or next to confined spaces.

19.0 %Vol
Possible unnoticeable adverse physiological effects (CSB / CGA).
16.0 %Vol
Possible increased pulse and breathing rate, impaired thinking and attention, and reduced coordination; UK HSE L101 warns levels below 16 %Vol can cause unconsciousness and death.
14.0 %Vol
Possible abnormal fatigue on exertion, emotional upset, faulty coordination and poor judgment.
12.5 %Vol
Possible very poor judgment and coordination, impaired respiration that may cause permanent heart damage, nausea and vomiting.
Below 10 %Vol
Possible inability to move, loss of consciousness, convulsions and death; inhaling oxygen-free air can cause collapse within seconds (UK HSE L101).
Above 23.5 %Vol
Oxygen enrichment sharply increases the flammability of clothing and combustible materials; standard compressed-air breathing gear cannot be used above 23.5 %Vol (OSHA 29 CFR 1910.134; UK HSE L101).

Workplace oxygen thresholds and standards

Oxygen has no toxic exposure limit like H2S or CO. Workplace standards instead define safe oxygen boundaries, pre-entry conditions and ambient alarm set points.

Normal ambient air
20.9 %Vol (UK HSE L101; US CSB Safety Bulletin).
US OSHA confined spaces
Below 19.5 %Vol is an oxygen-deficient atmosphere and above 23.5 %Vol is an oxygen-enriched atmosphere (29 CFR 1910.146 general industry; 1926.1202 construction).
US OSHA respiratory protection
Below 19.5 %Vol is oxygen-deficient and treated as immediately dangerous to life or health (29 CFR 1910.134).
UK HSE L101
Advises investigating any departure from 20.9 %Vol, highlights fire risk under enrichment and unconsciousness below 16 %Vol, and advises testing oxygen before flammable and toxic gases (para 96).
China national standards
GB 8958-2006 (clause 3.1) defines below 19.5 %Vol as oxygen deficiency; GB 30871-2022 (clause 6.3 a) requires 19.5%–21 %Vol before hazardous-chemical confined-space entry and no more than 23.5 %Vol in oxygen-enriched spaces; GB/T 50493-2019 (clause 5.5.2) recommends 19.5 %Vol low and 23.5 %Vol high ambient O2 alarms for applicable petrochemical designs.

Which Eranntex O2 models fit each job

Clip-on personal protection
Choose BTYQ-MS104K-S2 when workers need SOS and man-down alerts or optional 4G and GPS/BeiDou tracking—it runs at least 48 hours with live transmission active and carries 1–2 gases standard (3 custom). Choose the single-gas BTYQ-MS104K-S1 when crews want an IP68 clip-on without daily charging; its non-rechargeable battery lasts 1–2 years at 8 hours per day in 0–30 %Vol.
Confined-space pre-entry and multi-gas patrols
BTYQ-MS400-S pairs a built-in pump (at least 20 hours pumped runtime, supplied 0.2 m gooseneck probe) with one-button switching to diffusion for 1–4 gases, expandable to 6. For higher channel counts, look at BTYQ-MS600-S (1–7 gases standard, up to 9 custom, over 24 hours), BTYQ-MS600-S1 (1–6 gases), BTYQ-MS600-S2 (1–10 gases), or the diffusion-first BTYQ-MS104K-M with its supplied external pump.
Dedicated single-gas O2 sampling
BTYQ-MS104K-L combines a single oxygen channel with a built-in pump—12 hours on pump or over 100 hours in diffusion with the pump off—across 0–30 %Vol and 0–100 %Vol.
Fixed room monitoring and exhaust interlocks
GTYQ-MIC-500S and GTYQ-MIC-500S-CB monitor a single O2 point on 24 V DC with 4–20 mA, RS485 and two relay outputs to drive exhaust fans or door beacons. When oxygen must be watched alongside other gases, choose GTYQ-MIC-600 (1–6 gases) or GTYQ-MIC-600-CB (up to 8 gases). Both CB models add magnetic-wand and infrared-remote adjustment under Ex db IIC T6 Gb so technicians can tune settings without opening the flameproof housing.
Temporary area coverage
BTYQ-PTM600-S (pumped, up to 24 gases, over 30 hours with a 0.4 m stainless-steel sampling handle) and BTYQ-PTM600-S2 (diffusion with optional pump, 1–6 gases) cover turnarounds and temporary work zones.

Field engineering trade-offs from Eranntex O2 projects

Pressurized pipelines and closed-loop return
Standard electrochemical O2 sensors cannot take direct line pressure—even around 0.2 MPa (2 bar) can force electrolyte leakage and chamber seal failure. In pressurized combustible process lines where sample gas cannot vent to atmosphere, Eranntex builds a closed sample loop using an inlet isolation valve, pressure-reducing regulator, flowmeter, sensor chamber, explosion-proof return pump and return isolation valve.
Corrosive or hydrogen-rich background gas
Where corrosive chemical vapors or hydrogen streams attack standard electrochemical cells, Eranntex can configure an optical (fluorescence) O2 sensor—for example on a DN50 PN16 flange insertion or split chamber—for multi-percent monitoring. Because optical fluorescence loses accuracy below roughly 1 %Vol, trace oxygen measurements below 1 %Vol call for a different sensing approach confirmed per project.
Deep pits and covered vaults without power
Lowering a full transmitter into a 6–8 m covered pit blocks wireless signals and turns battery service into a confined-space entry. Separating the sensor chamber on an extension cable keeps the display, power pack and wireless link above ground while sensing oxygen down in the pit.
Post-inerting clearance and sample pretreatment
After nitrogen inerting or fire-suppression discharge, fixed O2 monitors mounted on nearby piping with local audio-visual alarms verify when surrounding air has returned to safe entry levels. For hot, humid or dusty process gas, MIC-600 configurations pair with Eranntex sample-pretreatment units matched to temperature and moisture.

What to confirm before requesting an O2 quote

Measuring range
Use 0–30 %Vol (0.01 %Vol resolution) for worker safety around 19.5 %Vol and 23.5 %Vol. Use 0–100 %Vol for inerting, nitrogen purging or oxygen-rich processes; trace ppm options are confirmed by model and process conditions.
Fixed detector placement
Cover occupied work areas and worker breathing height first, then account for leak sources, ventilation paths, gas accumulation pockets and cold-gas release behavior rather than applying one fixed height rule.
Calibration and testing order
Follow the operating manual for your exact model and O2 sensor configuration when calibrating or bump testing. Before confined-space entry, OSHA 29 CFR 1910.146 requires testing oxygen first—followed by flammable and toxic gases—and UK HSE L101 (para 96) advises the same sequence because catalytic combustible sensors rely on oxygen.
Multi-gas combinations
On multi-gas detectors, oxygen is optional and the sensor combination and ranges are confirmed for each order.
Trace ppm, sensor life and special atmospheres
Because trace ppm ranges, sensor selection, expected service life and suitability for high-CO2 or high-altitude sites vary with the background gas and model, share your gas composition, altitude, temperature and maintenance expectations with our sales engineers so we can confirm the right configuration.

O2 measuring ranges by model

Each filled square is a measuring range the model can be configured with. Ranges, sensor combinations and resolution are confirmed for each order.

O2 measuring ranges (%Vol), each from 0 to the value shown, offered by each model
Model30100Sampling
Portable Gas Detectors
MS104K-LPump
MS104K-MDiffusion (standard) or Pump (standard)
MS104K-S1Diffusion
MS104K-S2Diffusion
MS400-SDiffusion (standard) or Pump (standard)
MS600-SPump
MS600-S1Pump
MS600-S2Pump
Transportable Gas Detection Systems
PTM600-SPump
PTM600-S2Diffusion
Fixed Gas Detectors
MIC-500SDiffusion
MIC-500S-CBDiffusion
MIC-600Diffusion
MIC-600-CBDiffusion
O2 measuring ranges (ppm), each from 0 to the value shown, offered by each model
Model1,0005,00050,000Sampling
Portable Gas Detectors
MS104K-S2Diffusion
Fixed Gas Detectors
MIC-500SDiffusion
MIC-600Diffusion
Resolution and sampling details by model

%Vol ranges

O2 measuring ranges and resolution by model (%Vol)
Product modelProduct categoryMeasuring rangeResolutionSamplingProduct link
BTYQ-MS104K-LPortable Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
PumpView BTYQ-MS104K-L
BTYQ-MS104K-MPortable Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
Diffusion (standard) or Pump (standard)View BTYQ-MS104K-M
BTYQ-MS104K-S1Portable Gas Detectors
  • 0–30
  • 0.01 %Vol
DiffusionView BTYQ-MS104K-S1
BTYQ-MS104K-S2Portable Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
DiffusionView BTYQ-MS104K-S2
BTYQ-MS400-SPortable Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
Diffusion (standard) or Pump (standard)View BTYQ-MS400-S
BTYQ-MS600-SPortable Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
PumpView BTYQ-MS600-S
BTYQ-MS600-S1Portable Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
PumpView BTYQ-MS600-S1
BTYQ-MS600-S2Portable Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
PumpView BTYQ-MS600-S2
BTYQ-PTM600-STransportable Gas Detection Systems
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
PumpView BTYQ-PTM600-S
BTYQ-PTM600-S2Transportable Gas Detection Systems
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
DiffusionView BTYQ-PTM600-S2
GTYQ-MIC-500SFixed Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
DiffusionView GTYQ-MIC-500S
GTYQ-MIC-500S-CBFixed Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
DiffusionView GTYQ-MIC-500S-CB
GTYQ-MIC-600Fixed Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
DiffusionView GTYQ-MIC-600
GTYQ-MIC-600-CBFixed Gas Detectors
  • 0–30
  • 0–100
  • 0.01 %Vol
  • 0.01 %Vol
DiffusionView GTYQ-MIC-600-CB

ppm ranges

O2 measuring ranges and resolution by model (ppm)
Product modelProduct categoryMeasuring rangeResolutionSamplingProduct link
BTYQ-MS104K-S2Portable Gas Detectors
  • 0–5,000
  • 1 ppm
DiffusionView BTYQ-MS104K-S2
GTYQ-MIC-500SFixed Gas Detectors
  • 0–1,000
  • 0–50,000
  • 1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-500S
GTYQ-MIC-600Fixed Gas Detectors
  • 0–5,000
  • 1 ppm
DiffusionView GTYQ-MIC-600

Each row lists the O2 ranges a model can be configured with. The sensor combination and range for your unit are set when the order is confirmed.

Where O2 is monitored

Engineering Resources

CHECKLIST & TOOLSGas Detector Quotation Preparation Checklist
View checklist

Gas detection questions

Define the O2 detection requirement

Provide the required unit and range, monitoring task, sampling method, deployment type, operating environment, applicable standard or jurisdiction, and any other gases that must be monitored.

Compare the options or discuss the requirement.

Send the gases, ranges and monitoring task. Our sales engineers confirm the configuration and reply with a quotation.