Skip to content
Industrial gas detection for demanding environments

Fixed Gas Detectors

GTYQ-MIC-600 Fixed Multigas Detector

GTYQ-MIC-600

Product overview

A fixed multigas detection platform with local display, data logging and configurable industrial outputs.

Configurable fixed multigas monitoring

GTYQ-MIC-600 is a fixed multigas detection platform configurable for continuous monitoring of one to six gases at industrial installations. The installed gases, ranges and sensing principles are selected for the application.

The 2.5-inch color display shows local readings and alarms. Data logging, RS485 and 4–20 mA outputs support the monitoring point; any wireless link depends on the selected configuration.

Sampling method
Diffusion
Ingress protection
IP66
Operating temperature
-20 °C to 55 °C

Contact us to confirm the gas combination and measuring ranges for your application.

Technical specifications

Confirmed technical specifications
Ingress protectionIP66
Dimensions240 × 180 × 90 mm standard chamber; 240 × 230 × 90 mm with alarm; 260 × 180/230 × 90 mm with the expanded chamber
Weight2.2 kg — 2.7 kg with alarm; expanded chamber configurations are 2.4 kg or 2.9 kg with alarm.
Operating temperature-20 °C to 55 °C
Display size2.5 in
Sampling methodDiffusion
Standard gas configuration
1–6 gases
Signal output
RS485 Modbus RTU and three-wire 4–20 mA standard; HART 5 optional
Typical accuracy
≤ ±2% FS; higher-accuracy sensor option available
Linearity
≤ ±1%
Repeatability
≤ ±1%
Measurement uncertainty
≤ ±1%
Response time
T90 ≤ 30 s
Recovery time
≤ 30 s
Power supply
24 V DC
Installation
Wall, pipeline, flow-through or pumped sampling
Local operation
4-key keypad and infrared remote control

Supported gas configurations

Review the documented gas and measuring-range options, then request compatibility confirmation for the required configuration.

0 gases selected · up to 6Select one measuring range for each required gas.
Gas

Combustible Gas · EX

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Oxygen · O₂

Measuring range0–30 %Vol
Resolution0 %Vol
Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Carbon Monoxide · CO

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Measuring range0–100,000 ppm
Resolution1 ppm
Gas

Hydrogen Sulfide · H₂S

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–10,000 ppm
Resolution1 ppm

For gases not listed in this table, contact technical sales to discuss your requirements.

Read all 138 documented gas and measuring-range options
Gas

Hydrogen Sulfide · H₂S

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Carbon Monoxide · CO

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Measuring range0–100,000 ppm
Resolution1 ppm
Gas

Oxygen · O₂

Measuring range0–30 %Vol
Resolution0 %Vol
Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Methane · CH₄

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Carbon Dioxide · CO₂

Measuring range0–20 %Vol
Resolution0 %Vol
Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–500 ppm
Resolution1 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Measuring range0–50,000 ppm
Resolution1 ppm
Gas

Ammonia · NH₃

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Chlorine · Cl₂

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–20 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Gas

Sulfur Dioxide · SO₂

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–20 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–500 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Nitric Oxide · NO

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Nitrogen Dioxide · NO₂

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Hydrogen · H₂

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–1,000 ppm
Resolution0 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Measuring range0–40,000 ppm
Resolution1 ppm
Gas

Hydrogen Cyanide · HCN

Measuring range0–30 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Gas

Hydrogen Chloride · HCl

Measuring range0–20 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Gas

Phosphine · PH₃

Measuring range0–5 ppm
Resolution0 ppm
Measuring range0–25 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Combustible Gas · EX

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Chlorine Dioxide · ClO₂

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Gas

Ethylene Oxide · ETO

Measuring range0–100 %LEL
Resolution1 %LEL
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution0 ppm
Gas

Phosgene · COCl₂

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Silane · SiH₄

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Fluorine · F₂

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Hydrogen Fluoride · HF

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Formaldehyde · CH₂O

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Hydrogen Bromide · HBr

Measuring range0–50 ppm
Resolution0 ppm
Gas

Diborane · B₂H₆

Measuring range0–10 ppm
Resolution0 ppm
Gas

Arsine · AsH₃

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Ozone · O₃

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–5 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–30,000 ppm
Resolution1 ppm
Gas

Germane · GeH₄

Measuring range0–2 ppm
Resolution0 ppm
Measuring range0–20 ppm
Resolution0 ppm
Gas

Hydrazine · N₂H₄

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–300 ppm
Resolution0 ppm
Gas

Tetrahydrothiophene · THT

Measuring range0–100 mg/m3
Resolution0 mg/m3
Gas

Bromine · Br₂

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Acetylene · C₂H₂

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution0 ppm
Gas

Ethylene · C₂H₄

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Gas

Ethanol · C₂H₆O

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Methanol

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Nitrogen Oxides · NOₓ

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Carbon Disulfide · CS₂

Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution0 ppm
Gas

Acrylonitrile · C₃H₃N

Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Nitrous Oxide · N₂O

Measuring range0–100 ppm
Resolution0 ppm
Gas

Methylamine

Measuring range0–50 ppm
Resolution0 ppm
Gas

Nitrogen · N₂

Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Benzene · C₆H₆

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Styrene · C₈H₈

Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Vinyl Chloride · C₂H₃Cl

Measuring range0–100 ppm
Resolution0 ppm
Gas

Trichloroethylene · C₂HCl₃

Measuring range0–100 ppm
Resolution0 ppm
Gas

Tetrachloroethylene (PID) · C₂Cl₄

Measuring range0–100 ppm
Resolution0 ppm
Gas

Methyl Bromide · CH₃Br

Measuring range0–200 g/m3
Resolution0 g/m3
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–30,000 ppm
Resolution1 ppm
Gas

Helium · He

Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Argon · Ar

Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Xenon · Xe

Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Nitrogen Trifluoride · NF₃

Measuring range0–100 ppm
Resolution0 ppm
Gas

Hydrogen Peroxide · H₂O₂

Measuring range0–100 ppm
Resolution0 ppm
Gas

Sulfuryl Fluoride · SO₂F₂

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Acetaldehyde

Measuring range0–10 ppm
Resolution0 ppm
Gas

Iodine · I₂

Measuring range0–50 ppm
Resolution0 ppm

Communication and product capabilities

Included as standard

Confirmed product-wide interfaces and functions
  • RS485

Options for technical review

Select requirements for technical confirmation
0 selectedSelections are added to your enquiry and require configuration confirmation.
  • HARTOptional

Certificates & documents

Preview of Environmental Labeling (Type II) Product Verification Certificate ZII26080321001
Certificate

Environmental Labeling (Type II) Product Verification Certificate ZII26080321001

ZII26080321001

View document
Preview of China Type Approval Certificate (CPA) 2026C508-44
Certificate

China Type Approval Certificate (CPA) 2026C508-44

2026C508-44

View document
Preview of China Explosion-Proof Certificate of Conformity CE24.5822X
Certificate

China Explosion-Proof Certificate of Conformity CE24.5822X

CE24.5822X

View document

Downloads

datasheetGTYQ-MIC-600 English technical summary
Open PDF
ENGINEERING GUIDEHow to Define an Industrial Gas Leak Detection Project
Read guide

Compare adjacent models

Discuss your requirements

Selected product

GTYQ-MIC-600

Eranntex GTYQ-MIC-600 fixed gas detector with an orange enclosure and audible and visual alarm.

Select the required gases and measuring ranges, and review the listed communication options. Technical sales will confirm compatibility and the final configuration with you.

Request product information

Tell us about your requirement

Choose up to 6 gases for this product. for other requirements.

Eranntex will use the information you provide to respond to your inquiry. Read our Privacy Policy and Website Terms of Use. Sending an inquiry does not authorize optional advertising.