Eranntex manufactures ammonia (NH3) detection across 15 models—8 portable, 2 transportable, 4 fixed and 1 online odor monitoring system (TH-2000-OU)—spanning 0–10 ppm to 0–10,000 ppm, 0–100 %LEL and 0–10 mg/m³ with diffusion or pump sampling. Choose a personal or handheld ammonia detector for breathing-zone safety and leak checks, a fixed ammonia gas detection system with relay interlocks for R717 refrigeration machinery rooms, chemical plants or poultry and livestock barns, or TH-2000-OU for continuous fence-line odor monitoring.

Where ammonia gas hazards occur and what NH3 levels do

Ammonia (NH3, CAS 7664-41-7) is a colorless, corrosive alkaline gas used as R717 refrigerant in cold storage and food processing, as a feedstock in fertilizer and chemical synthesis, and generated by manure decomposition in poultry houses, pig and livestock barns and wastewater treatment basins. NIOSH lists anhydrous ammonia at a relative gas density of 0.60 (molecular weight 17.0, boiling point -33.3 °C / -28 °F): gaseous NH3 is lighter than air and rises toward ceilings and exhaust intakes, though a pressurized liquid spray can briefly form a cold aerosol cloud that sinks before warming and rising. Because olfactory fatigue sets in quickly, smell cannot replace a calibrated ammonia alarm.

25–50 ppm
Occupational exposure band—NIOSH REL TWA 25 ppm, UK HSE WEL 25 ppm, AIHA ERPG-1 25 ppm and OSHA PEL 50 ppm.
100–200 ppm
Short-term emergency guidance band—NRC 1-hour EEGL 100 ppm and AIHA ERPG-2 200 ppm (NIOSH IDLH documentation).
300 ppm (IDLH)
Immediately dangerous to life or health (revised NIOSH IDLH); OSHA requires positive-pressure SCBA whenever exposure above 300 ppm is possible.
300–500 ppm
Reported maximum short-exposure tolerance for 30–60 minutes; human subjects exposed to 500 ppm for 30 minutes showed respiration-rate changes and moderate-to-severe irritation (NIOSH IDLH documentation).
2,500–6,000 ppm
Exposure for 30 minutes is considered dangerous to life (Smyth, cited in NIOSH IDLH documentation).
5,000–10,000 ppm
Reported fatal in short exposures, with a 5-minute human LCLo of 5,000 ppm (NIOSH IDLH documentation).
15–28 %Vol (150,000–280,000 ppm)
Flammable range in air (NIOSH Pocket Guide); OSHA’s Ammonia Refrigeration guidance warns that mixing ammonia with compressor lubricating oil widens the flammable range in enclosed machinery rooms.

Ammonia exposure limits, alarm levels and compliance standards

Keep the instrument measuring range, occupational exposure limit (OEL), ammonia alarm levels and 15 %Vol LEL distinct when specifying an ammonia gas monitor. Statutory regulations set legal ceilings, while engineering standards guide alarm set points and ventilation interlocks.

US OSHA PEL (statutory)
50 ppm (35 mg/m³) 8-hour TWA under 29 CFR 1910.1000 Table Z-1.
US OSHA PSM threshold (statutory)
10,000 lb for anhydrous ammonia and 15,000 lb for ammonia solutions above 44% by weight under 29 CFR 1910.119 Appendix A.
US NIOSH REL & IDLH (recommended)
25 ppm (18 mg/m³) TWA, 35 ppm (27 mg/m³) 15-minute STEL and 300 ppm IDLH (NIOSH Pocket Guide & IDLH documentation).
US OSHA Ammonia Refrigeration (guidance)
Highlights 300 ppm IDLH, 15%–28 %Vol flammability (widened by lubricating oil) and references IIAR practices for refrigeration safety controls.
UK HSE WEL (statutory)
25 ppm (18 mg/m³) 8-hour TWA and 35 ppm (25 mg/m³) 15-minute STEL for anhydrous ammonia (HSE EH40/2005, 4th edition).
China GBZ 2.1-2019 (statutory OEL)
PC-TWA 20 mg/m³ and PC-STEL 30 mg/m³ for workplace air.
China GB/T 50493-2019 (petrochemical design)
Recommends a 0–300% OEL measuring range, first-stage alarm at or below 100% OEL, second-stage alarm at or below 200% OEL (clauses 5.5.1–5.5.2) and mounting lighter-than-air detectors within 2.0 m above the release source (clause 6.1.2).
China GB 50072-2021 (cold storage)
Requires audio-visual alarm and forced emergency exhaust at 150 ppm in ammonia machinery rooms, plus emergency power shutoff at 25 %LEL (clauses 7.4.1 and 7.4.3).

Portable, fixed and online ammonia gas detectors by task

Personal clip-on ammonia detector
Choose the ammonia single gas detector BTYQ-MS104K-S1 when technicians need an IP68 diffusion alarm in 0–100 ppm without daily charging (1–2 years non-rechargeable battery life at 8 hours per day). Choose BTYQ-MS104K-S2 (IP68, at least 48 hours runtime with 4G and GPS/BeiDou active) when crews need SOS and man-down alerts or wider NH3 ranges (0–50, 0–100, 0–1,000, 0–5,000 ppm and 0–100 %LEL) across 1–2 standard gases (3 custom).
Handheld and portable ammonia detector with pump
BTYQ-MS104K-L is a single-gas handheld ammonia detector with a built-in pump (12 hours pumped or over 100 hours in diffusion with the pump off) for checking overhead valves and manifolds. For multi-gas ammonia leak detection, BTYQ-MS400-S (IP68, at least 20 hours pumped runtime, supplied 0.2 m gooseneck probe, one-button switch to diffusion, 1–4 gases expandable to 6) and BTYQ-MS104K-M (diffusion-first at least 100 hours with supplied external pump) cover routine patrols. High-channel teams needing a portable ammonia gas detector with 0–10 ppm (0.001 ppm resolution) alongside VOC or combustible channels choose BTYQ-MS600-S (IP68, over 24 hours, 1–7 gases up to 9 custom), BTYQ-MS600-S1 (1–6 gases) or BTYQ-MS600-S2 (1–10 gases).
Transportable area ammonia monitor
BTYQ-PTM600-S (pumped, over 30 hours with a 0.4 m stainless-steel sampling handle, up to 24 gases, 0–10 ppm at 0.001 ppm through 0–5,000 ppm and 0–100 %LEL) and BTYQ-PTM600-S2 (diffusion, 1–6 gases) cover turnarounds, tank purging and temporary work zones.
Fixed ammonia gas detection system and alarms
GTYQ-MIC-500S and GTYQ-MIC-500S-CB provide single-point 24 V DC IP66 NH3 monitoring with 4–20 mA, RS485 and two relay outputs to drive exhaust fans, door beacons or shutoff valves—with GTYQ-MIC-500S extending from 0–50 ppm (suited to poultry and livestock ventilation) up to 0–10,000 ppm and 0–100 %LEL. Where ammonia must be watched alongside CO2, H2S or combustibles, choose GTYQ-MIC-600 (1–6 gases) or GTYQ-MIC-600-CB (up to 8 gases). Both CB models allow magnetic-wand and infrared-remote adjustment under Ex db IIC T6 Gb without opening the enclosure.
Online fence-line and odor ammonia monitoring
TH-2000-OU is a dedicated online odor monitoring system configured with an NH3 gas sensor channel in 0–10 mg/m³ (0.01 mg/m³ resolution) for wastewater treatment plants, composting sites and industrial perimeter compliance.

Field engineering trade-offs in ammonia gas monitoring

Sample-line adsorption and PTFE tubing
Standard rubber or PVC hoses strongly adsorb polar NH3 gas, which can drive remote pumped readings down to a false 0 ppm before sample gas reaches the sensor. For remote pumped ammonia gas leak detector checks, specify PTFE-lined sample tubing and keep line runs as short as practical.
High-temperature, high-humidity process exhaust
In a process duct running near 75 °C and 90 %RH, upstream high-concentration NH3 and downstream low-concentration scrubbed exhaust could not share one sensing principle. Eranntex split the architecture into a TDLAS laser cabinet with cooling and two-stage condensation dehumidification upstream and an electrochemical unit with dehumidification downstream. Factory gas testing also showed that filter media can adsorb ammonia, confirming that sample pretreatment and the detector must be flow-tested together as one assembly.
Splitting multi-gas portable fleets by zone
Rather than stacking every sensor into one handheld across a multi-area chemical site, Eranntex configured MS600-series units by zone hazard—grouping NH3 + VOC + LEL for alkaline/solvent units and LEL + CO + H2S for utility zones—paired with wireless upload to the site platform.
Refrigeration machinery rooms and wastewater detention basins
Fixed MIC-500S and MIC-600 transmitters wired over 4–20 mA to controllers or PLCs handle both low-ppm toxicity alarms (30 ppm or 150 ppm ventilation triggers) and 25 %LEL shutdown interlocks alongside CO2 or other refrigerants, with cable shielding against heavy motor interference. In humid wastewater basins where NH3 and H2S occur together, pairing moisture filtration with an H2S-resistant electrochemical ammonia gas sensor keeps low-ppm readings stable.

How to specify an ammonia gas sensor and alarm system

Measuring range and unit
Pick 0–10, 0–50 or 0–100 ppm for worker safety around 25–50 ppm OELs and poultry, pig or livestock barn ventilation; 0–1,000, 0–5,000 or 0–10,000 ppm for machinery-room leak escalation and process streams; 0–100 %LEL for explosive-level shutdown interlocks; and TH-2000-OU (0–10 mg/m³) for continuous odor monitoring.
Mounting position and ventilation
Because gaseous NH3 is lighter than air (relative density 0.60), mount fixed detectors above likely leak points such as compressor seals, flanges, ammonia pumps and relief headers (GB/T 50493-2019 recommends within 2.0 m above the source; GB 50072-2021 places machinery-room detectors at the top of protected spaces and near exhaust intakes). Avoid stagnant dead zones and verify airflow paths.
Sensing principle and harsh operating conditions
Ammonia sensor selection depends on site conditions—electrochemical cells cover most ambient ppm duties, while high-concentration exhaust, sub-zero cold storage, dusty humid poultry or livestock barns, condensing moisture (above 90 %RH) or background H2S, amines and halogens can cause poisoning, adsorption or cross-interference. Share your temperature, humidity, background gases, explosion-proof certification and range needs with Eranntex engineers rather than assuming one default sensor.
Order-confirmed manufacturing and factory audits
On multi-gas detectors, ammonia is optional and Eranntex confirms the exact sensor combination, sensing principle, sample tubing and measurement range for each order directly at the factory, with on-site factory audits welcome. Follow the specific model manual for zeroing, bump testing and calibration.

NH3 measuring ranges by model

Each filled square is a measuring range the model can be configured with. Ranges, sensor combinations and resolution are confirmed for each order.

NH3 measuring ranges (ppm), each from 0 to the value shown, offered by each model
Model10501001,0005,00010,000Sampling
Portable Gas Detectors
MS104K-LPump
MS104K-MDiffusion (standard) or Pump (standard)
MS104K-S1Diffusion
MS104K-S2Diffusion
MS400-SDiffusion (standard) or Pump (standard)
MS600-SPump
MS600-S1Pump
MS600-S2Pump
Transportable Gas Detection Systems
PTM600-SPump
PTM600-S2Diffusion
Fixed Gas Detectors
MIC-500SDiffusion
MIC-500S-CBDiffusion
MIC-600Diffusion
MIC-600-CBDiffusion
NH3 measuring ranges (%LEL), each from 0 to the value shown, offered by each model
Model100Sampling
Portable Gas Detectors
MS104K-LPump
MS104K-MDiffusion (standard) or Pump (standard)
MS104K-S2Diffusion
MS400-SDiffusion (standard) or Pump (standard)
MS600-SPump
MS600-S1Pump
MS600-S2Pump
Transportable Gas Detection Systems
PTM600-SPump
PTM600-S2Diffusion
Fixed Gas Detectors
MIC-500SDiffusion
MIC-500S-CBDiffusion
MIC-600Diffusion
MIC-600-CBDiffusion
NH3 measuring ranges (mg/m3), each from 0 to the value shown, offered by each model
Model10Sampling
Gas Monitoring and Analysis Systems
TH-2000-OUDiffusion
Resolution and sampling details by model

ppm ranges

NH3 measuring ranges and resolution by model (ppm)
Product modelProduct categoryMeasuring rangeResolutionSamplingProduct link
BTYQ-MS104K-LPortable Gas Detectors
  • 0–10
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
PumpView BTYQ-MS104K-L
BTYQ-MS104K-MPortable Gas Detectors
  • 0–10
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
Diffusion (standard) or Pump (standard)View BTYQ-MS104K-M
BTYQ-MS104K-S1Portable Gas Detectors
  • 0–100
  • 0.01 ppm
DiffusionView BTYQ-MS104K-S1
BTYQ-MS104K-S2Portable Gas Detectors
  • 0–50
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView BTYQ-MS104K-S2
BTYQ-MS400-SPortable Gas Detectors
  • 0–10
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
Diffusion (standard) or Pump (standard)View BTYQ-MS400-S
BTYQ-MS600-SPortable Gas Detectors
  • 0–10
  • 0–50
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 0.1 ppm
PumpView BTYQ-MS600-S
BTYQ-MS600-S1Portable Gas Detectors
  • 0–10
  • 0–50
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 0.1 ppm
PumpView BTYQ-MS600-S1
BTYQ-MS600-S2Portable Gas Detectors
  • 0–10
  • 0–50
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 0.1 ppm
PumpView BTYQ-MS600-S2
BTYQ-PTM600-STransportable Gas Detection Systems
  • 0–10
  • 0–50
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 0.1 ppm
PumpView BTYQ-PTM600-S
BTYQ-PTM600-S2Transportable Gas Detection Systems
  • 0–10
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView BTYQ-PTM600-S2
GTYQ-MIC-500SFixed Gas Detectors
  • 0–50
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0–10,000
  • 0.01 ppm
  • 0.01 ppm
  • 1 ppm
  • 1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-500S
GTYQ-MIC-500S-CBFixed Gas Detectors
  • 0–10
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-500S-CB
GTYQ-MIC-600Fixed Gas Detectors
  • 0–50
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-600
GTYQ-MIC-600-CBFixed Gas Detectors
  • 0–10
  • 0–100
  • 0–1,000
  • 0–5,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-600-CB

%LEL ranges

NH3 measuring ranges and resolution by model (%LEL)
Product modelProduct categoryMeasuring rangeResolutionSamplingProduct link
BTYQ-MS104K-LPortable Gas Detectors
  • 0–100
  • 0.1 %LEL
PumpView BTYQ-MS104K-L
BTYQ-MS104K-MPortable Gas Detectors
  • 0–100
  • 0.1 %LEL
Diffusion (standard) or Pump (standard)View BTYQ-MS104K-M
BTYQ-MS104K-S2Portable Gas Detectors
  • 0–100
  • 0.1 %LEL
DiffusionView BTYQ-MS104K-S2
BTYQ-MS400-SPortable Gas Detectors
  • 0–100
  • 0.1 %LEL
Diffusion (standard) or Pump (standard)View BTYQ-MS400-S
BTYQ-MS600-SPortable Gas Detectors
  • 0–100
  • 0.1 %LEL
PumpView BTYQ-MS600-S
BTYQ-MS600-S1Portable Gas Detectors
  • 0–100
  • 0.1 %LEL
PumpView BTYQ-MS600-S1
BTYQ-MS600-S2Portable Gas Detectors
  • 0–100
  • 0.1 %LEL
PumpView BTYQ-MS600-S2
BTYQ-PTM600-STransportable Gas Detection Systems
  • 0–100
  • 0.1 %LEL
PumpView BTYQ-PTM600-S
BTYQ-PTM600-S2Transportable Gas Detection Systems
  • 0–100
  • 0.1 %LEL
DiffusionView BTYQ-PTM600-S2
GTYQ-MIC-500SFixed Gas Detectors
  • 0–100
  • 0.1 %LEL
DiffusionView GTYQ-MIC-500S
GTYQ-MIC-500S-CBFixed Gas Detectors
  • 0–100
  • 0.1 %LEL
DiffusionView GTYQ-MIC-500S-CB
GTYQ-MIC-600Fixed Gas Detectors
  • 0–100
  • 0.1 %LEL
DiffusionView GTYQ-MIC-600
GTYQ-MIC-600-CBFixed Gas Detectors
  • 0–100
  • 0.1 %LEL
DiffusionView GTYQ-MIC-600-CB

mg/m3 ranges

NH3 measuring ranges and resolution by model (mg/m3)
Product modelProduct categoryMeasuring rangeResolutionSamplingProduct link
TH-2000-OUGas Monitoring and Analysis Systems
  • 0–10
  • 0.01 mg/m3
DiffusionView TH-2000-OU

Each row lists the NH3 ranges a model can be configured with. The sensor combination and range for your unit are set when the order is confirmed.

Where NH3 is monitored

Engineering Resources

APPLICATION NOTEWastewater H₂S Monitoring: Setting Up the Gas Sampling System for Humid Tank Air
Read application note
ENGINEERING GUIDEHow to Define an Industrial Gas Leak Detection Project
Read guide
CHECKLIST & TOOLSGas Detector Quotation Preparation Checklist
View checklist

Gas detection questions

Define the NH3 detection requirement

Provide the required unit and range, monitoring task, sampling method, deployment type, operating environment, applicable standard or jurisdiction, and any other gases that must be monitored.

Compare the options or discuss the requirement.

Send the gases, ranges and monitoring task. Our sales engineers confirm the configuration and reply with a quotation.