Skip to content
Industrial gas detection for demanding environments

Fixed Gas Detectors

GTYQ-MIC-500S Fixed Single-Gas Detector

GTYQ-MIC-500S

Product overview

A fixed detector for continuous monitoring of one selected gas with industrial analog and digital outputs.

Continuous fixed single-gas monitoring

GTYQ-MIC-500S is a fixed detector for continuously monitoring one selected toxic, combustible or other target gas. Diffusion measurement is used for standard fixed installation, with pipeline or pumped arrangements available where the sampling conditions require them.

The detector supports 4–20 mA and RS485 Modbus RTU communication, relay alarming and non-intrusive infrared operation. The gas, range, sensor principle and output configuration are selected for the monitoring point.

Sampling method
Diffusion
Ingress protection
IP66
Operating temperature
-20 °C to 55 °C

Contact us to confirm the gas combination and measuring ranges for your application.

Technical specifications

Confirmed technical specifications
Ingress protectionIP66
Dimensions240 × 160 × 90 mm; 240 × 220 × 90 mm with alarm (L × W × H)
Weight1.4 kg — 1.6 kg with the audio-visual alarm.
Operating temperature-20 °C to 55 °C
Sampling methodDiffusion
Display size1.7 in
Data storage> 100,000 records
Standard gas configuration
1 gas
Expanded gas configuration
No higher gas-count expansion documented
Typical measurement accuracy
≤ ±3% FS; higher-accuracy sensors available
Response time
T90 ≤ 30 s
Recovery time
≤ 30 s
Operating humidity
10–95% RH, non-condensing
Power supply
24 V DC; 220 V AC optional
Signal output
RS485 Modbus RTU and three-wire 4–20 mA standard; two-wire 4–20 mA optional
Alarm output
One dry-contact output standard; two available as an option; local audible and visual alarm optional
Wireless options
433 MHz, LoRa, Wi-Fi, 4G/5G and NB-IoT configurations
Explosion protection
Ex db IIC T6 Gb / Ex tb IIIC T80 °C Db
Standard accessories
Operating instructions, product conformity document, warranty card, infrared remote control and outer packaging
Local operation
3-key keypad and infrared remote control

Supported gas configurations

Review the documented gas and measuring-range options, then request compatibility confirmation for the required configuration.

0 gases selected · up to 1Select one measuring range for each required gas.
Gas

Combustible Gas · EX

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Oxygen · O₂

Measuring range0–30 %Vol
Resolution0 %Vol
Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–50,000 ppm
Resolution1 ppm
Gas

Carbon Monoxide · CO

Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–500 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Measuring range0–100,000 ppm
Resolution1 ppm
Gas

Hydrogen Sulfide · H₂S

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Measuring range0–50,000 ppm
Resolution1 ppm

For gases not listed in this table, contact technical sales to discuss your requirements.

Read all 160 documented gas and measuring-range options
Gas

Hydrogen Sulfide · H₂S

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Measuring range0–50,000 ppm
Resolution1 ppm
Gas

Carbon Monoxide · CO

Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–500 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Measuring range0–100,000 ppm
Resolution1 ppm
Gas

Oxygen · O₂

Measuring range0–30 %Vol
Resolution0 %Vol
Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–50,000 ppm
Resolution1 ppm
Gas

Methane · CH₄

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Carbon Dioxide · CO₂

Measuring range0–10 %Vol
Resolution0 %Vol
Measuring range0–20 %Vol
Resolution0 %Vol
Measuring range0–50 %Vol
Resolution0 %Vol
Measuring range0–2,000 ppm
Resolution1 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Measuring range0–50,000 ppm
Resolution1 ppm
Gas

Ammonia · NH₃

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Chlorine · Cl₂

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–20 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Gas

Sulfur Dioxide · SO₂

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–20 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–500 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Nitric Oxide · NO

Measuring range0–25 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Nitrogen Dioxide · NO₂

Measuring range0–20 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Hydrogen · H₂

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 %Vol
Resolution0 %Vol
Measuring range0–1,000 ppm
Resolution0 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Measuring range0–40,000 ppm
Resolution1 ppm
Gas

Volatile Organic Compounds · VOC

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Hydrogen Cyanide · HCN

Measuring range0–30 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Gas

Hydrogen Chloride · HCl

Measuring range0–20 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Phosphine · PH₃

Measuring range0–5 ppm
Resolution0 ppm
Measuring range0–25 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Combustible Gas · EX

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Chlorine Dioxide · ClO₂

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Gas

Ethylene Oxide · ETO

Measuring range0–100 %LEL
Resolution1 %LEL
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Gas

Phosgene · COCl₂

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Silane · SiH₄

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Gas

Fluorine · F₂

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Hydrogen Fluoride · HF

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Formaldehyde · CH₂O

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Gas

Hydrogen Bromide · HBr

Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Diborane · B₂H₆

Measuring range0–10 ppm
Resolution0 ppm
Gas

Arsine · AsH₃

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–10 ppm
Resolution0 ppm
Gas

Ozone · O₃

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Measuring range0–30,000 ppm
Resolution1 ppm
Gas

Germane · GeH₄

Measuring range0–2 ppm
Resolution0 ppm
Measuring range0–20 ppm
Resolution0 ppm
Gas

Hydrazine · N₂H₄

Measuring range0–1 ppm
Resolution0 ppm
Measuring range0–300 ppm
Resolution0 ppm
Gas

Tetrahydrothiophene · THT

Measuring range0–100 mg/m3
Resolution0 mg/m3
Gas

Bromine · Br₂

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–50 ppm
Resolution0 ppm
Gas

Acetylene · C₂H₂

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Ethylene · C₂H₄

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Ethanol · C₂H₆O

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Methanol

Measuring range0–100 %LEL
Resolution0 %LEL
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Nitrogen Oxides · NOₓ

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Carbon Disulfide · CS₂

Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Acrylonitrile · C₃H₃N

Measuring range0–50 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–2,000 ppm
Resolution1 ppm
Gas

Nitrous Oxide · N₂O

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Methylamine

Measuring range0–50 ppm
Resolution0 ppm
Gas

Benzene · C₆H₆

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Gas

Toluene · C₇H₈

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–20,000 ppm
Resolution1 ppm
Gas

Xylene · C₈H₁₀

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–200 ppm
Resolution0 ppm
Gas

Styrene · C₈H₈

Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–6,000 ppm
Resolution1 ppm
Gas

Vinyl Chloride · C₂H₃Cl

Measuring range0–200 ppm
Resolution0 ppm
Gas

Trichloroethylene · C₂HCl₃

Measuring range0–200 ppm
Resolution0 ppm
Gas

Tetrachloroethylene (PID) · C₂Cl₄

Measuring range0–200 ppm
Resolution0 ppm
Gas

Methyl Bromide · CH₃Br

Measuring range0–200 g/m3
Resolution0 g/m3
Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Helium · He

Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Argon · Ar

Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Xenon · Xe

Measuring range0–100 %Vol
Resolution0 %Vol
Gas

Nitrogen Trifluoride · NF₃

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Sulfuryl Fluoride · SO₂F₂

Measuring range0–200 ppm
Resolution0 ppm
Measuring range0–5,000 ppm
Resolution1 ppm
Gas

Acetaldehyde

Measuring range0–10 ppm
Resolution0 ppm
Gas

Total Volatile Organic Compounds · TVOC

Measuring range0–10 ppm
Resolution0 ppm
Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–1,000 ppm
Resolution1 ppm
Measuring range0–10,000 ppm
Resolution1 ppm
Gas

Iodine · I₂

Measuring range0–50 ppm
Resolution0 ppm
Gas

Sulfur Hexafluoride · SF₆

Measuring range0–100 ppm
Resolution0 ppm
Measuring range0–3,000 ppm
Resolution1 ppm

Communication and product capabilities

Included as standard

Confirmed product-wide interfaces and functions
  • RS485
  • Infrared

Options for technical review

Select requirements for technical confirmation
0 selectedSelections are added to your enquiry and require configuration confirmation.
  • HARTOptional
  • LoRaOptional
  • 4GOptional
  • NB-IoTOptional
  • Wi-FiOptional

Certificates & documents

Preview of Environmental Labeling (Type II) Product Verification Certificate ZII26080321001
Certificate

Environmental Labeling (Type II) Product Verification Certificate ZII26080321001

ZII26080321001

View document
Preview of China Explosion-Proof Certificate of Conformity CE24.5821X
Certificate

China Explosion-Proof Certificate of Conformity CE24.5821X

CE24.5821X

View document
Preview of China Explosion-Proof Certificate of Conformity CE23.5160X
Certificate

China Explosion-Proof Certificate of Conformity CE23.5160X

CE23.5160X

View document
Preview of China Compulsory Certification (CCC) 2026081801000376
Certificate

China Compulsory Certification (CCC) 2026081801000376

2026081801000376

View document

Downloads

datasheetGTYQ-MIC-500S English technical summary
Open PDF

Compare adjacent models

Discuss your requirements

Selected product

GTYQ-MIC-500S

Front view of the Eranntex GTYQ-MIC-500S fixed flameproof single gas detector featuring a 1.7-inch color LCD display and integrated audio-visual alarm strobe.

Select the required gases and measuring ranges, and review the listed communication options. Technical sales will confirm compatibility and the final configuration with you.

Request product information

Tell us about your requirement

Choose up to 1 gas for this product. for other requirements.

Eranntex will use the information you provide to respond to your inquiry. Read our Privacy Policy and Website Terms of Use. Sending an inquiry does not authorize optional advertising.